Specification
Meets ANSI/EIA/TIA 568-B.2-10 requirements
Meets general purpose cable UL-1581 CM rating
Meets fire retardant low smoke IEC60332-1 rating
Meets ISO/IEC 2nd edition 11801 Amendment 1.2
Meets ISO/IEC 61156-2 2nd edition & CENELEC EN 50288-10-1
Tested up to 650MHz
Description
Copper cable, 4 pairs, Category 6A, Solid, 500MHz
Cable is used for indoor installation
Material
Conductive material: Soft annealed electrolytic copper
Conductor insulation: HDPE, film-porous-film structure
The cable jacket: PVC
Meets ANSI/EIA/TIA 568-B.2-10 requirements
Meets general purpose cable UL-1581 CM rating
Meets fire retardant low smoke IEC60332-1 rating
Meets ISO/IEC 2nd edition 11801 Amendment 1.2
Meets ISO/IEC 61156-2 2nd edition & CENELEC EN 50288-10-1
Tested up to 650MHz
Description
Copper cable, 4 pairs, Category 6A, Solid, 500MHz
Cable is used for indoor installation
Material
Conductive material: Soft annealed electrolytic copper
Conductor insulation: HDPE, film-porous-film structure
The cable jacket: PVC
Technical Characteristic
Conductor diameter: 0.58 ± 0.02 mm (23AWG)
Insulation diameter: 1.1 ± 0.01 mm
Insulation thickness: Minimum 0.208 mm, Average 0.25 mm
Insulation elongation: Minimum 300%
Insulation tensile strength: Minimum 1.682 Kg/mm²
Sheath thickness: Minimum 0.75mm, Average 0.80 mm
Conductor diameter: 0.58 ± 0.02 mm (23AWG)
Insulation diameter: 1.1 ± 0.01 mm
Insulation thickness: Minimum 0.208 mm, Average 0.25 mm
Insulation elongation: Minimum 300%
Insulation tensile strength: Minimum 1.682 Kg/mm²
Sheath thickness: Minimum 0.75mm, Average 0.80 mm
Sheath diameter: 10.5 ± 0.3 mm (0.41")
Sheath elongation: Minimum 100%
Sheath tensile strength: Minimum 1.407 Kg/mm²
Operating temperature: -30°C – +70°C (-22°F – +158°F)
Weight per 1000 ft (304.8 m): 21.3 kg (47.7 lbs)
Standard package: 304.8 m (1000 ft)
Sheath elongation: Minimum 100%
Sheath tensile strength: Minimum 1.407 Kg/mm²
Operating temperature: -30°C – +70°C (-22°F – +158°F)
Weight per 1000 ft (304.8 m): 21.3 kg (47.7 lbs)
Standard package: 304.8 m (1000 ft)
Electrical Characteristic | |||||||
Frequency, MHz | Pair Attenuation, dB/100m | NEXT losses, dB | PS NEXT, dB | ||||
1 | 2.1 | 74.3 | 72.3 | ||||
10 | 5.9 | 59.3 | 57.3 | ||||
100 | 19.1 | 44.3 | 42.3 | ||||
200 | 27.6 | 39.8 | 37.8 | ||||
250 | 31.1 | 38.3 | 36.3 | ||||
300 | 34.3 | 37.1 | 35.1 | ||||
400 | 40.1 | 35.3 | 33.3 | ||||
500 | 45.3 | 33.8 | 31.8 |
Dielectric strength |
2.5kV/3 seconds | |
Insulation resistance test | Min. 150MΩ/km | |
Conductor resistance at 20°C (68°F) | 9.38Ω/100m (2.9Ω/100ft) | |
DC Resistance Unbalance | 2% | |
Pair-to-Ground Capacitance Unbalance | 160pF/100m (51pF/100 ft) | |
Impedance 1-500 MHz | 100Ω-115Ω | |
Mutual Capacitance | 5.6nF/m (1.7nF/ft) | |
Spark Test | 2.5kV |
Ordering Information
HI6AUS-M-C
i-Net Networks Horizontal Indoor Cable Category6A UTP Solid 23AWG 4 Pair Milky Gray CM
M
M—Milky Gray, B—Blue, L—Black, G—Green, R—Red, Y—Yellow
C
C—CM, L—LSZH P—Plenum