Specification
Meets ANSI/EIA/TIA 568-B.2-1 requirements
Meets general purpose cable UL-1581 CM rating
Meets fire retardant low smoke IEC60332-1 rating
Meets plenum UL-910 rating
Description
Shielded Copper cable, 4 pairs, category 6, solid
4 separately foil-shielded twisted pairs
Cable is used for indoor installation
Material
Conductive material: wire made of soft annealed electrolytic copper
Conductor insulation: HDPE
The cable jacket: PVC / LSZH / Plenum
Every pair is separately 100% shielded with polyester aluminum foil
Meets ANSI/EIA/TIA 568-B.2-1 requirements
Meets general purpose cable UL-1581 CM rating
Meets fire retardant low smoke IEC60332-1 rating
Meets plenum UL-910 rating
Description
Shielded Copper cable, 4 pairs, category 6, solid
4 separately foil-shielded twisted pairs
Cable is used for indoor installation
Material
Conductive material: wire made of soft annealed electrolytic copper
Conductor insulation: HDPE
The cable jacket: PVC / LSZH / Plenum
Every pair is separately 100% shielded with polyester aluminum foil
Technical Characteristic
Conductor diameter: 0.56 ± 0.01 mm (0.022" ± 0.0004") (23 AWG)
Insulated conductor diameter: 1.43 mm (0.056")
Outer cable diameter: 7.8 mm (0.3")
Jacket thickness: 0.7 mm (0.0275")
Pulling strength: 130 N maximum
Minimum bend radius: 8xØ while installation, 6xØ while vertical cabling, 4xØ while horizontal cabling
Conductor diameter: 0.56 ± 0.01 mm (0.022" ± 0.0004") (23 AWG)
Insulated conductor diameter: 1.43 mm (0.056")
Outer cable diameter: 7.8 mm (0.3")
Jacket thickness: 0.7 mm (0.0275")
Pulling strength: 130 N maximum
Minimum bend radius: 8xØ while installation, 6xØ while vertical cabling, 4xØ while horizontal cabling
Conductor elongation: 14% minimum
Rip cord has a breaking strength of 10 kg (98 N)
Drain wire diameter: 0.5 mm (0.01968")
Installation temperature is -5°C – +50°C (+23°F – +122°F)
Operating temperature: -20°C – +60°C (-4°F – +140°F)
Weight per 1000 ft (304.8 m): 23 AWG 16.4 kg (36.16 lbs)
Standard package: 304.8 m (1000 ft)
Electrical Characteristic | |||||||
Frequency, MHz | Pair Attenuation, dB/100m (dB/100ft) | NEXT, dB | PS NEXT, dB |
PP ELFEXT, dB/100m (dB/100ft) |
PS ELFEXT, dB/100m (dB/100ft) | RL, dB | |
1 | 2 (0.6) | 80 | 77 | 75 (22.86) | 72 (21.94) | 20 | |
4 | 3.8 (1.16) | 80 | 77 | 75 (22.86) | 72 (21.94) | 23 | |
10 | 6(1.83) | 80 | 77 | 75 (22.86) | 72 (21.94) |
25 | |
16 | 7.6 (2.32) | 80 | 77 | 75 (22.86) | 72 (21.94) | 25 | |
20 | 8.5 (2.59) | 80 | 77 | 75 (22.86) | 72 (21.94) | 25 | |
31.25 | 10.7 (3.26) | 80 | 77 | 75 (22.86) | 72 (21.94) | 23.6 | |
62.5 | 15.4 (4.69) | 80 | 77 | 75 (22.86) | 72 (21.94) | 22 | |
100 | 19.8 (6.03) | 80 | 77 | 70 (21.34) | 67 (20.42) | 21 | |
125 | 22.4 (6.83) | 70 | 67 | 65 (19.81) | 62 (19.90) | 20 | |
200 | 29 (8.84) | 70 | 67 | 60 (18.29) | 57 (17.37) | 19 | |
250 | 35.6 (10.85) | 70 | 67 | 55 (16.77) | 52 (15.04) | 18 |
Maximum conductor resistance at 20°C (68°F) | 73.0Ω/km (117.48Ω/mile) | |
Resistance unbalance | 2% max. | |
Resistance at the frequency of 1-250 MHz | 100 ± 15% | |
Transfer impedance at the frequency of 1 MHz | 50MΩ/m (15.24MΩ/ft) max. | |
Transfer impedance at the frequency of 10 MHz | 100MΩ/m (30.48MΩ/ft) max. | |
Transfer impedance at the frequency of 30 MHz | 200MΩ/m (60.69MΩ/ft) max. | |
Insulation resistance at 20°C (68°F) | 152MΩ/km (244.62MΩ/mile) min. | |
Capacitive unbalance at the frequency of 1 kHz | 1.5pF/m (0.46pF/ft) | |
Capacity at the frequency of 1 kHz | 43pF/m (13.1pF/ft) | |
Maximum voltage | 60V RMS | |
Dielectric rigidity | 700V per minute | |
Propagation velocity | 80% | |
Max. derivation of propagation delay at freq. of 1-250 MHz | 25ns/100m (7.62ns/100 ft) |
Ordering Information
HI06TSM-C
i-Net Networks Horizontal Indoor Cable Category6 SSTP Solid 23AWG 4Pair Milky Gray CM